WTW Ion Selective Electrodes ISE
Contact us for pricing
Lead-Time: Approximately 2 weeks
Contact our office to request a quote or to order these items.
Potassium, Fluoride, Aluminium, Phosphate, Lithium, Ammonium, Copper, Cyanide, Chloride, Sodium, Calcium, Magensium, Silver, Nitrate, Bromide
Ion-selective and gas-sensitive electrodes are used for measuring the dissolved concentration of specific ions or gases in water. Similar to the pH electrode, the membrane interacts with the dissolved ions and delivers a concentration-dependent voltage signal that is converted to the corresponding measurement result.
Highlights
Space-saving through integrated reference electrode
broad selection of applications including ammonium measurement
Slim and space-saving design with 12 mm shaft diameter
Contact us for pricing
Lead-Time: Approximately 2 weeks
Contact our office to request a quote or to order these items.
Potassium, Fluoride, Aluminium, Phosphate, Lithium, Ammonium, Copper, Cyanide, Chloride, Sodium, Calcium, Magensium, Silver, Nitrate, Bromide
Ion-selective and gas-sensitive electrodes are used for measuring the dissolved concentration of specific ions or gases in water. Similar to the pH electrode, the membrane interacts with the dissolved ions and delivers a concentration-dependent voltage signal that is converted to the corresponding measurement result.
Highlights
Space-saving through integrated reference electrode
broad selection of applications including ammonium measurement
Slim and space-saving design with 12 mm shaft diameter
Contact us for pricing
Lead-Time: Approximately 2 weeks
Contact our office to request a quote or to order these items.
Potassium, Fluoride, Aluminium, Phosphate, Lithium, Ammonium, Copper, Cyanide, Chloride, Sodium, Calcium, Magensium, Silver, Nitrate, Bromide
Ion-selective and gas-sensitive electrodes are used for measuring the dissolved concentration of specific ions or gases in water. Similar to the pH electrode, the membrane interacts with the dissolved ions and delivers a concentration-dependent voltage signal that is converted to the corresponding measurement result.
Highlights
Space-saving through integrated reference electrode
broad selection of applications including ammonium measurement
Slim and space-saving design with 12 mm shaft diameter
Ammonium ISE
Item 106395: Ammonia gas-sensitive combination electrode with plug head, 0.02 to 900 mg/l, requires ionic strength adapter MZ/NH3/CN standard solution ES/NH4. 3 exchange heads and 50 ml electrolyte solution.
Silver-/Sulphide ISE
Item 106651: Silver ion/sulfide combined ion selective electrode, 1 m (3.3 ft) cable, DIN plug, 0.003 to 32,000 mg/l, requires ELY/BR/503 reference electrolyte, ionic strength adapter ISA/FK (Ag-ions) or according instruction manual for sulfide measurement. Standard solutions have to be prepared freshly.
Combined Calcium ISE
Item 106655: Combined Calcium ion selective electrode, with 3.3 ft (1 m) cable, DIN plug, 0.02 to 40,000 mg/l, requires ELY/BR/503 reference electrolyte, ionic strength adapter ISA/Ca standard solution ES/Ca. Delivery contains electrolyte and exchange heads.
Sodium ISE
Item 106649: Sodium ion selective glass alectrode with S7 plug head, reference electrolyte 3 mol/l KCl. Measuring range 0.01 mg/l … 23,000 mg/l. (0,000001 mol/l to 1 mol/l). Requires standard solution ES/Na, ion strenght adjustment solution ISA/Na, cable AS/DIN or AS/BNC
Bromide ISE
Item 106653: Combined Bromide selective electrode, 3.3 ft (1 m) cable, DIN plug, 0.4 to 79,000 mg/l, requires ELY/BR/503 reference electrolyte, ionic strength adapter ISA/FK, standard solution ES/Br. Delivery contains electrolyte!
Chloride ISE
Item 106661: Combined Chloride selective electrode, with 3.3 ft (1 m) cable, DIN plug, 2 to 35,000 mg/l, requires ELY/BR/503 reference electrolyte, ionic strength adapter ISA/FK, standard solution ES/Cl. Delivery contains electrolyte!
Combined Cyanide ISE
Item 106663: Combined Cyanide selective electrode, with 3.3 ft (1 m) cable, DIN plug, 0.2 to 260 mg/l requires ELY/BR/503 reference electrolyte, ionic strength adapter MZ/NH3/CN. Standard solutions have to be prepared freshly. Delivery contains electrolyte!
Combined Copper ISE
Item 106665: Combined Copper ion selective electrode, with 3.3 ft (1 m) cable, DIN plug, 0.0006 to 6400 mg/l, requires ELY/BR/503 reference electrolyte, ionic strength adapter ISA/FK, standard solution ES/Cu. Delivery contains electrolyte!
Combined Fluoride
Item 106666: Combined Fluoride selective electrode, with 3.3 ft (1 m) cable, BNC plug, 0.02 mg/l to saturation, requires ELY/BR/503 reference electrolyte, ionic strength adapter TISAB, standard solution ES/F. Delivery contains electrolyte!
Or
Item 106667: Combined Fluoride selective electrode, with 3.3 ft (1 m) cable, DIN plug, 0.02 mg/l to saturation, requires ELY/BR/503 reference electrolyte, ionic strength adapter TISAB, standard solution ES/F. Delivery contains electrolyte!
Combined Potassium ISE
Item 106671: Combined Potassium ion selective electrode, with 3.3 ft (1 m) cable, DIN plug, 0.04 to 39,000 mg/l, requires ELY/BR/503/K reference electrolyte, ionic strength adapter ISA/K, standard solution ES/K. Delivery contains electrolyte and exchange heads.
Combined Nitrate ISE
Item 106675: Combined Nitrate selective electrode, with 3.3 ft (1 m) cable, DIN plug, 0.4 to 62,000 mg/l, requires ELY/BR/503/N reference electrolyte, ionic strength adapter TISAB/NO3, standard solution ES/NO3. Delivery contains electrolyte and exchange heads.