6308 TuSS Turbidity and Suspended Solids Controller and Transmitter

from $600.00

BRAND: JENCO

The 6308TuSS (Turbidity and SuspendedSolids)System is a rugged microprocessor based instrument housed in a watertight ¼ DIN case, designed for use inlaboratories and process control applications. The model 6308TuSS microprocessor performs self-diagnostic routine every time you turn on the unit providing you with basic information on the stability of the instrument. The system simultaneously displays Turbidity and SuspendedSolids, relay status and current output in one graphic LCDscreen.The 6308TuSS is equipped with 3 relays (2programmable high or low relay for Turbidity and Suspended Solids, 1 programmable for external cleaning); Turbidity an dSuspended Solids relays are hysteresis driven and configurableto CENTER mode. The system also has a isolated 4-20mA analog output for the Turbidity and Suspended Solids display.

Shipping Time: (3 - 4 weeks from time of order)

OPTIONS:
Quantity:
Add To Cart

BRAND: JENCO

The 6308TuSS (Turbidity and SuspendedSolids)System is a rugged microprocessor based instrument housed in a watertight ¼ DIN case, designed for use inlaboratories and process control applications. The model 6308TuSS microprocessor performs self-diagnostic routine every time you turn on the unit providing you with basic information on the stability of the instrument. The system simultaneously displays Turbidity and SuspendedSolids, relay status and current output in one graphic LCDscreen.The 6308TuSS is equipped with 3 relays (2programmable high or low relay for Turbidity and Suspended Solids, 1 programmable for external cleaning); Turbidity an dSuspended Solids relays are hysteresis driven and configurableto CENTER mode. The system also has a isolated 4-20mA analog output for the Turbidity and Suspended Solids display.

Shipping Time: (3 - 4 weeks from time of order)

BRAND: JENCO

The 6308TuSS (Turbidity and SuspendedSolids)System is a rugged microprocessor based instrument housed in a watertight ¼ DIN case, designed for use inlaboratories and process control applications. The model 6308TuSS microprocessor performs self-diagnostic routine every time you turn on the unit providing you with basic information on the stability of the instrument. The system simultaneously displays Turbidity and SuspendedSolids, relay status and current output in one graphic LCDscreen.The 6308TuSS is equipped with 3 relays (2programmable high or low relay for Turbidity and Suspended Solids, 1 programmable for external cleaning); Turbidity an dSuspended Solids relays are hysteresis driven and configurableto CENTER mode. The system also has a isolated 4-20mA analog output for the Turbidity and Suspended Solids display.

Shipping Time: (3 - 4 weeks from time of order)

 

 

Features

  • 1/4 DIN watertight, IP65 rated enclosure

  • Reversible & isolated 4 to 20 mA output with adjustable bandwidth

  • Power down, non-volatile memory backup

  • Multiple spots on/off relays

  • 1 to 5 point calibration

  • Graphical LCD display with backlight

  • Electrode self-cleaning function

  • An embedded self-diagnostic program

  • RS-485 Modbus output

  • 4-digit password security protection

  • High 50/60 Hz noise rejection

  • CE compliant


SPECIFICATIONS

Turbidity Range 1: —————————————————-0.00 to 100.00 NTU (FTU) (TC-100)

Turbidity Resolution 1: ———————————————0.01

Turbidity Accuracy 1: ———————————————-± 3% F.S.

Turbidity Self Cleaning 1: —————————————-30 Mins.

Turbidity Range 2: —————————————————0.0 to 500.0 NTU (FTU) (TC-500)

Turbidity Resolution 2: ———————————————0.1

Turbidity Accuracy 2: ———————————————-±3% F.S.

Turbidity Self Cleaning 2: —————————————-10 Mins.

Turbidity Range 3: —————————————————-0 to 3000 NTU (FTU) (TC-3000)

Turbidity Recognition 3:——————————————- 1

Turbidity Accuracy 3: ————————————————±3% F.S.

Turbidity Self Cleaning 3: ——————————————-10 Mins.

Suspend Solid Range 1: ———————————————-0.0 to 1000 mg/L (TCS-1000)

Suspend Solid Resolution 1: —————————————1

Suspend Solid Accuracy 1: —————————————-±3% F.S.

Turbidity Self Cleaning 1: ——————————————-10 Mins.

Suspend Solid Range 2: ———————————————0 to 50000 mg/L (TCS-MXS-A)

Suspend Solid Resolution 2: —————————————1

Suspend Solid Accuracy 2: —————————————±3% F.S.