WTW Portable Turbidity Meter Turb 430 IR
BRAND: WTW/Xylem
MODEL: TURB 430 IR
Turbidity measurement acc. To DIN ISO 27027 for any demand up tp 1100 NTU with lab option
Turb® 430 IR meet the requirements of nephelometric measurement at 90° stray light for drinking water with highest precision particularly suitable in the range < 1 NTU and is therefore suitable for water analysis,control, such, fuel, cell cultures, food and beverage industries and (health) administration surveillance.
• Measuring range comprises 0.02 -1100 NTU/FNU with automatic measuring range switching
• Adjustable calibration intervals and GLP-compliant documentation
• Stray light behavior according to pharmacopoeia 5.0
• Higly precise AMCO Clear® Standards
BRAND: WTW/Xylem
MODEL: TURB 430 IR
Turbidity measurement acc. To DIN ISO 27027 for any demand up tp 1100 NTU with lab option
Turb® 430 IR meet the requirements of nephelometric measurement at 90° stray light for drinking water with highest precision particularly suitable in the range < 1 NTU and is therefore suitable for water analysis,control, such, fuel, cell cultures, food and beverage industries and (health) administration surveillance.
• Measuring range comprises 0.02 -1100 NTU/FNU with automatic measuring range switching
• Adjustable calibration intervals and GLP-compliant documentation
• Stray light behavior according to pharmacopoeia 5.0
• Higly precise AMCO Clear® Standards
BRAND: WTW/Xylem
MODEL: TURB 430 IR
Turbidity measurement acc. To DIN ISO 27027 for any demand up tp 1100 NTU with lab option
Turb® 430 IR meet the requirements of nephelometric measurement at 90° stray light for drinking water with highest precision particularly suitable in the range < 1 NTU and is therefore suitable for water analysis,control, such, fuel, cell cultures, food and beverage industries and (health) administration surveillance.
• Measuring range comprises 0.02 -1100 NTU/FNU with automatic measuring range switching
• Adjustable calibration intervals and GLP-compliant documentation
• Stray light behavior according to pharmacopoeia 5.0
• Higly precise AMCO Clear® Standards
The measurement and automatic 3-point calibration runs menu-guided. The calibration takes place via an AMCO Clear® standard set (0.02-10-1000 NTU). Up to 1000 data sets including sample ID numbers can be stored and later put out GLP-compliant via the PC software LSdata . The quality assurance of the measured results is supported by calibration interval setting with documentation. This makes Turb® 430 not only a portable meter – also available in a practical field set - but also a precise and reliable benchtop meter for applications of up to 1100 NTU/FNU with optimized data administration!
-
TURB 430 IR SET (PN 600321)
Portable turbidimeter (90°, Infrared) acc. DIN EN 27027 incl. calibration standard kit (0.02-10-1000 NTU/FNU) in field case with table insert and accessories: Kal.Kit, 5 empty cuvette (28 mm), cleaning tissues, screw driver, PC-software Lsdata, PC cable AK 540 B, instruction. Optional: LabStation LS Flex/430 with PC-software LSdata Flex/430 for GLP-compliant data export and rechargeable batteries RB Flex/430 (order no. 251 301) or rechargeable batteries RB Flex/430 (order no. 251 300), PC software LSdata Flex/430 (stand alone, order no. 902762).
TURB 430 IR (PN 600320)
Portable turbidimeter for nephelometric measurement (90°) acc. DIN EN 27027, incl. calibration standard kit (0.02 - 10 - 1000 NTU/FNU), 5 empty cuvette, tissues, batt. (4 AA Mignon), suitable for drinking water. Optional: LabStation LS Flex/430 with software package LSdata Flex/430 for GLP-compliant data export and rech.batt. RB Flex/430 (order no. 251 301) or rechargeable batteries RB Flex/430 (order no. 251 300, PC software LSdata Flex/430 (stand alone 902762).
-
Light source LED
pH measurement yes
Turbidity measurement yes
Calibration interval/record yes
Cal. adjustment for selected programs no
Special methods with pH and Temp. yes
User-defined progr. via LSdata Software 100
Data storage 1000
Sets available
Rechargeable batteries w. universal plug optional
Methods/programs ca. 200
Cells / Cuvettes: round 16 mm ( H:91-104 mm); 28 mm
Ident number yes
Interface RS232
PC-Connection yes
Method-update via Internet yes
Firmware-update via Internet yes
LabStation for lab use incl. rechargeable battery + PC Software LSdata optional
LSdata Stand alone optional optional
Certificates CE/ETLus/cETL
Waterproof housing IP 67