ProCon IS750 Series Ion Selective Electrodes
MFR: Icon Process Controls
The advanced IS750 ion sensors provide precise and reliable measurement of key ions, including fluoride, chloride, ammonium, and ammonia. Designed for accuracy and durability, these sensors ensure consistent performance across a wide range of applications, from environmental monitoring to industrial processes. Trust our ion sensors for accurate, real-time data to support your critical decision-making.
Features
High Precision
Robust Design
M12 | Flying Lead
3/4″ NPT Connection
Call or email us for pricing and product availability
MFR: Icon Process Controls
The advanced IS750 ion sensors provide precise and reliable measurement of key ions, including fluoride, chloride, ammonium, and ammonia. Designed for accuracy and durability, these sensors ensure consistent performance across a wide range of applications, from environmental monitoring to industrial processes. Trust our ion sensors for accurate, real-time data to support your critical decision-making.
Features
High Precision
Robust Design
M12 | Flying Lead
3/4″ NPT Connection
Call or email us for pricing and product availability
MFR: Icon Process Controls
The advanced IS750 ion sensors provide precise and reliable measurement of key ions, including fluoride, chloride, ammonium, and ammonia. Designed for accuracy and durability, these sensors ensure consistent performance across a wide range of applications, from environmental monitoring to industrial processes. Trust our ion sensors for accurate, real-time data to support your critical decision-making.
Features
High Precision
Robust Design
M12 | Flying Lead
3/4″ NPT Connection
Call or email us for pricing and product availability
-
Slope: 56 ± 3 mV between 10-100 ppm @ 25°C
Reproducibility: ± 2%
Interferences: S-2, I-1, CN-1, Br-1
Complexation: Heavy metals
Temp. Range: 0 - 80°C | 32 - 176°F
Pressure Range: 0 - 70 Psi
Response Time: 95% response in 30 seconds
Storage: Long term, store dry; Short term, store in dilute chloride standard
Concentration Range: 1.8 ppm to Saturated (5 x 10-6 M to Saturated)
pH Range: 2 to 12 pH
Resistance < 1 megaohm
Care, Maintenance & Cleaning: Polish with polishing strips Treat with a dilute ISA
Isopotential Point: 50,000 ppm
On-Line Capability: Yes
-
Slope: 56 ± 2 mV between 10-100 ppm @ 25°C
Reproducibility: ± 2%
Interferences: OH-1
Complexation: Al+3, Fe+3, H+1 Temp. Range 0°C - 80°C | 32°F - 176°F
Pressure Range 0 - 70 Psi
Response Time 95% response in 30 seconds
Storage Long term, store dry; Short term, store in dilute fluoride standard with TISAB added
Concentration: Range 0.02 ppm to Saturated (1 x 10-6 M to Saturated) pH Range: 5 to 8 pH
Resistance 100 to 200 kiloohms
Care, Maintenance & Cleaning: Polish with polishing strips Treat with a dilute ISA
Isopotential Point: 20 ppm
On-Line Capability Yes, pH control required
-
Slope: 56 ± 3 mV between 10-100 ppm @ 25°C
Reproducibility: ± 2%
Interferences: Volatile weak acids Temp. Range: 0 - 50°C | 32 - 122°F
Complexation: Heavy metals
Pressure Range: 0 - 10 Psi
Response Time: 95% response in 30 seconds
Storage: Long term, store dry; Short term, store in carbon dioxide standard with ISA added
Concentration Range 4.4 ppm to 440 ppm (1 x 10-4 M to 1 x 10-2 M)
pH Range: 4.8 to 5.2 pH Resistance 1000 to 1500 megaohms
Care, Maintenance & Cleaning Treat with a dilute nitrogen oxide standard with pH adjusted to 4.8 - 5.2. Replace membrane as needed
On-Line Capability: Yes, pH control required
-
Slope: 26 ± 2 mV between 10-100ppm @ 25°C
Reproducibility: ± 2%
Interferences: Pb2+, Hg2+, Cu2+, Ni2+
Temp. Range: 0 to 40° C (if calibrated at that temp.)
Pressure Range: 0 to 30 psi
Response Time: 95% response in 30 seconds
Storage: Long term, store dry; Short term, store in dilute calcium standard
Concentration Range: 0.5 ppm to Saturated (5 x 10-6 M to Saturated)
pH Range: 3 to 10 pH
Resistance: 100 megaohms
Care, Maintenance & Cleaning: Treat with distilled water followed by calcium standard
Isopotential Point 1 ppm
On-Line Capability: Yes
-
Slope: 56 ± 3 mV between 10-100 ppm @ 25°C
Reproducibility: ± 2%
Interferences: SO2, HF, acetic acid Temp. Range: 0°C - 50°C | 32°F - 122°F
Pressure Range: 0 - 10 Psi Response Time: 95% response in 30 seconds
Storage Long: term, store dry;Short term, store in nitrogen oxide standard with ISA added
Concentration: Range 0.2 ppm to 220 ppm (5 x 10-6 M to 5 x 10-3 M)
pH Range: 1.1 to 1.7 pH Resistance 1000 to 1500 megaohms
Care, Maintenance & Cleaning: Treat with a dilute nitrogen oxide standard with pH adjusted to 1.1 - 1.7 Replace membrane as needed
On-Line Capability: Yes, pH control required
-
Slope: 56 ± 3 mV between 10-100 ppm @ 25°C
Reproducibility: ± 2%
Interferences: Cs+1, NH4+1
Temp. Range: 0 - 40°C | 0 - 104°F
Pressure Range: 0 - 30 Psi
Response Time: 95% response in 30 seconds
Storage: Long term, store dry;Short term, store in dilute potassium standard
Concentration Range: 0.04 ppm to Saturated (1 x 10-6 M to Saturated)
pH Range: 2 to 12 pH Resistance 100 megaohms
Care, Maintenance & Cleaning: Treat with distilled water followed by potassium standard
Isopotential: Point 20 ppm
On-Line Capability: Yes
-
Slope: 56 ± 3 mV between 10-100 ppm @ 25°C
Reproducibility: ± 2%
Interferences: K+1 Temp. Range 0 - 40°C | 32 - 104°F
Pressure Range: 0 - 30 Psi
Response Time: 95% response in 30 seconds
Storage: Long term, store dry;Short term, store in dilute ammonium standard
Concentration Range: 0.1 ppm to Saturated (5 x 10-6 M to Saturated)
pH Range: 4 to 10 pH
Resistance: 100 megaohms
Care, Maintenance & Cleaning Treat with distilled water followed by ammonium standard
Isopotential Point: 10 ppm
On-Line Capability: Yes
-
Slope: 56 ± 3 mV between 10-100 ppm @ 25°C
Reproducibility: ± 2%
Interferences: Volatile amines
Temp. Range: 0 - 50°C | 32 - 122°F
Pressure Range: 0 - 10 Psi
Response Time: 95% response in 30 seconds
Storage: Long term, store dry; Short term, store in ammonia standard with ISA added
Concentration Range: 0.01 ppm to 17,000 ppm (5 x 10-7 M to 1 M) pH Range Above 11 pH Resistance 1000 to 1500 megaohms
Care, Maintenance & Cleaning: Treat with a dilute ammonia standard with pH adjusted > pH 11 Replace membrane as needed
On-Line Capability: Yes, pH control required
-
Slope: 56 ± 3 mV between 10-100 ppm @ 25°C
Reproducibility: ± 2%
Interferences: SO2, HF, acetic acid
Pressure Range: 0 - 10 Psi
Temperature: 0 - 50°C | 32 -122°F
Response Time: 90% response in 30s
Concentration Range: 0.2 ppm to 220 ppm (5 x 10-6 M to 5 x 10-3 M)
pH Range 1.1 to 1.7 pH
-
Slope: 56 ± 3 mV between 10-100 ppm @ 25°C
Reproducibility: ± 2%
Interferences: SO2, HF, acetic acid
Temperature: 0 - 50°C | 32 - 122°F
Pressure Range: 0 - 10 Psi
Response Time: 95% response in 30s
Concentration Range: 0.2 ppm to 220 ppm (5 x 10-6 M to 5 x 10-3 M)
pH Range: 1.1 to 1.7pH