ProCon IS750 Series Ion Selective Electrodes

$0.00

MFR: Icon Process Controls

The advanced IS750 ion sensors provide precise and reliable measurement of key ions, including fluoride, chloride, ammonium, and ammonia. Designed for accuracy and durability, these sensors ensure consistent performance across a wide range of applications, from environmental monitoring to industrial processes. Trust our ion sensors for accurate, real-time data to support your critical decision-making.

Features

  • High Precision

  • Robust Design

  • M12 | Flying Lead 

  • 3/4″ NPT Connection

Call or email us for pricing and product availability

Part Number:
Quantity:
Add To Cart

MFR: Icon Process Controls

The advanced IS750 ion sensors provide precise and reliable measurement of key ions, including fluoride, chloride, ammonium, and ammonia. Designed for accuracy and durability, these sensors ensure consistent performance across a wide range of applications, from environmental monitoring to industrial processes. Trust our ion sensors for accurate, real-time data to support your critical decision-making.

Features

  • High Precision

  • Robust Design

  • M12 | Flying Lead 

  • 3/4″ NPT Connection

Call or email us for pricing and product availability

MFR: Icon Process Controls

The advanced IS750 ion sensors provide precise and reliable measurement of key ions, including fluoride, chloride, ammonium, and ammonia. Designed for accuracy and durability, these sensors ensure consistent performance across a wide range of applications, from environmental monitoring to industrial processes. Trust our ion sensors for accurate, real-time data to support your critical decision-making.

Features

  • High Precision

  • Robust Design

  • M12 | Flying Lead 

  • 3/4″ NPT Connection

Call or email us for pricing and product availability

 

  • Slope: 56 ± 3 mV between 10-100 ppm @ 25°C

    Reproducibility: ± 2%

    Interferences: S-2, I-1, CN-1, Br-1

    Complexation: Heavy metals

    Temp. Range: 0 - 80°C | 32 - 176°F

    Pressure Range: 0 - 70 Psi

    Response Time: 95% response in 30 seconds

    Storage: Long term, store dry; Short term, store in dilute chloride standard

    Concentration Range: 1.8 ppm to Saturated (5 x 10-6 M to Saturated)

    pH Range: 2 to 12 pH

    Resistance < 1 megaohm

    Care, Maintenance & Cleaning: Polish with polishing strips Treat with a dilute ISA

    Isopotential Point: 50,000 ppm

    On-Line Capability: Yes

  • Slope: 56 ± 2 mV between 10-100 ppm @ 25°C

    Reproducibility: ± 2%

    Interferences: OH-1

    Complexation: Al+3, Fe+3, H+1 Temp. Range 0°C - 80°C | 32°F - 176°F

    Pressure Range 0 - 70 Psi

    Response Time 95% response in 30 seconds

    Storage Long term, store dry; Short term, store in dilute fluoride standard with TISAB added

    Concentration: Range 0.02 ppm to Saturated (1 x 10-6 M to Saturated) pH Range: 5 to 8 pH

    Resistance 100 to 200 kiloohms

    Care, Maintenance & Cleaning: Polish with polishing strips Treat with a dilute ISA

    Isopotential Point: 20 ppm

    On-Line Capability Yes, pH control required

  • Slope: 56 ± 3 mV between 10-100 ppm @ 25°C

    Reproducibility: ± 2%

    Interferences: Volatile weak acids Temp. Range: 0 - 50°C | 32 - 122°F

    Complexation: Heavy metals

    Pressure Range: 0 - 10 Psi

    Response Time: 95% response in 30 seconds

    Storage: Long term, store dry; Short term, store in carbon dioxide standard with ISA added

    Concentration Range 4.4 ppm to 440 ppm (1 x 10-4 M to 1 x 10-2 M)

    pH Range: 4.8 to 5.2 pH Resistance 1000 to 1500 megaohms

    Care, Maintenance & Cleaning Treat with a dilute nitrogen oxide standard with pH adjusted to 4.8 - 5.2. Replace membrane as needed

    On-Line Capability: Yes, pH control required

  • Slope: 26 ± 2 mV between 10-100ppm @ 25°C

    Reproducibility: ± 2%

    Interferences: Pb2+, Hg2+, Cu2+, Ni2+

    Temp. Range: 0 to 40° C (if calibrated at that temp.)

    Pressure Range: 0 to 30 psi

    Response Time: 95% response in 30 seconds

    Storage: Long term, store dry; Short term, store in dilute calcium standard

    Concentration Range: 0.5 ppm to Saturated (5 x 10-6 M to Saturated)

    pH Range: 3 to 10 pH

    Resistance: 100 megaohms

    Care, Maintenance & Cleaning: Treat with distilled water followed by calcium standard

    Isopotential Point 1 ppm

    On-Line Capability: Yes

  • Slope: 56 ± 3 mV between 10-100 ppm @ 25°C

    Reproducibility: ± 2%

    Interferences: SO2, HF, acetic acid Temp. Range: 0°C - 50°C | 32°F - 122°F

    Pressure Range: 0 - 10 Psi Response Time: 95% response in 30 seconds

    Storage Long: term, store dry;Short term, store in nitrogen oxide standard with ISA added

    Concentration: Range 0.2 ppm to 220 ppm (5 x 10-6 M to 5 x 10-3 M)

    pH Range: 1.1 to 1.7 pH Resistance 1000 to 1500 megaohms

    Care, Maintenance & Cleaning: Treat with a dilute nitrogen oxide standard with pH adjusted to 1.1 - 1.7 Replace membrane as needed

    On-Line Capability: Yes, pH control required

  • Slope: 56 ± 3 mV between 10-100 ppm @ 25°C

    Reproducibility: ± 2%

    Interferences: Cs+1, NH4+1

    Temp. Range: 0 - 40°C | 0 - 104°F

    Pressure Range: 0 - 30 Psi

    Response Time: 95% response in 30 seconds

    Storage: Long term, store dry;Short term, store in dilute potassium standard

    Concentration Range: 0.04 ppm to Saturated (1 x 10-6 M to Saturated)

    pH Range: 2 to 12 pH Resistance 100 megaohms

    Care, Maintenance & Cleaning: Treat with distilled water followed by potassium standard

    Isopotential: Point 20 ppm

    On-Line Capability: Yes

  • Slope: 56 ± 3 mV between 10-100 ppm @ 25°C

    Reproducibility: ± 2%

    Interferences: K+1 Temp. Range 0 - 40°C | 32 - 104°F

    Pressure Range: 0 - 30 Psi

    Response Time: 95% response in 30 seconds

    Storage: Long term, store dry;Short term, store in dilute ammonium standard

    Concentration Range: 0.1 ppm to Saturated (5 x 10-6 M to Saturated)

    pH Range: 4 to 10 pH

    Resistance: 100 megaohms

    Care, Maintenance & Cleaning Treat with distilled water followed by ammonium standard

    Isopotential Point: 10 ppm

    On-Line Capability: Yes

  • Slope: 56 ± 3 mV between 10-100 ppm @ 25°C

    Reproducibility: ± 2%

    Interferences: Volatile amines

    Temp. Range: 0 - 50°C | 32 - 122°F

    Pressure Range: 0 - 10 Psi

    Response Time: 95% response in 30 seconds

    Storage: Long term, store dry; Short term, store in ammonia standard with ISA added

    Concentration Range: 0.01 ppm to 17,000 ppm (5 x 10-7 M to 1 M) pH Range Above 11 pH Resistance 1000 to 1500 megaohms

    Care, Maintenance & Cleaning: Treat with a dilute ammonia standard with pH adjusted > pH 11 Replace membrane as needed

    On-Line Capability: Yes, pH control required

  • Slope: 56 ± 3 mV between 10-100 ppm @ 25°C

    Reproducibility: ± 2%

    Interferences: SO2, HF, acetic acid

    Pressure Range: 0 - 10 Psi

    Temperature: 0 - 50°C | 32 -122°F

    Response Time: 90% response in 30s

    Concentration Range: 0.2 ppm to 220 ppm (5 x 10-6 M to 5 x 10-3 M)

    pH Range 1.1 to 1.7 pH

  • Slope: 56 ± 3 mV between 10-100 ppm @ 25°C

    Reproducibility: ± 2%

    Interferences: SO2, HF, acetic acid

    Temperature: 0 - 50°C | 32 - 122°F

    Pressure Range: 0 - 10 Psi

    Response Time: 95% response in 30s

    Concentration Range: 0.2 ppm to 220 ppm (5 x 10-6 M to 5 x 10-3 M)

    pH Range: 1.1 to 1.7pH

 
 
WTW Ion Selective Electrodes ISE